An industrial flare is a safety system for the controlled combustion of process gases in operation and relief scenarios. At AITESA we design and integrate flare systems for refineries, chemical and hydrogen plants, focusing on process safety and compliance.
Industrial flares for refineries and hydrogen plants
Got a concern about your flare system?
Tell us what you are seeing on site and what you are worried about. We will get back to you within 48 hours to understand the case and propose the most appropriate technical approach.
What is an industrial torch and when is it used?
A flare acts as a last safety element to manage process gases in conditions that do not allow their recovery. Its function is not to “burn for the sake of burning”, but to ensure controlled combustion when the system demands it.
Typical service situations:
-
Starts and stops
-
Controlled purging and venting
-
Maintenance operations
-
Relief scenarios and operational contingencies
Flares for hydrogen services
Hydrogen requires a specific approach due to its high reactivity, low ignition energy and the potential presence of oxygen (for example, in electrolysis-based processes).
Our flare systems are designed for:
- Hydrogen production facilities (electrolysis or pyrolysis routes).
- Purges, start-ups, shutdowns and maintenance operations.
- Streams containing H₂/O₂ mixtures.
Upstream of the flare, the system can include flow and composition measurement. Where oxygen is in excess, controlled methane injection can be incorporated to balance the mixture and maintain stable, safe combustion.
Types of industrial flare: what does your site need?
From a design and compliance standpoint, flares are commonly classified by their arrangement and by how combustion is assisted.
Elevated flare (visible flame)
- Visible flame at the tip; discharge at elevation
- Tolerant to variations in flow and gas composition
- Common choice for refineries and process plants
Enclosed ground flare (ground flare / enclosed flare)
- No visible flame; combustion contained within an enclosure
- Preferred where there are limits on thermal radiation, noise or visual impact
- Controlled air admission (natural draught or other design solutions as required)
Selection drivers on constrained sites
Final selection is typically driven by site constraints (thermal radiation, noise and visual impact), as well as the required flow range and gas composition. These factors often determine the flare type (elevated or enclosed) and its configuration.
Typical components of a flare system
Depending on project scope and plant philosophy, a flare package may include, in addition to the flare stack/enclosure:
- Flare tip and flame stabilisation devices
- A barrier between the process relief header and the flare (as required by the applicable standard)
- Ignition system and flame detection
- Instrumentation and associated control elements
- Utilities where applicable (for example, steam-assisted operation)
Process safety, compliance and HAZOP readiness
The safety configuration is defined against the applicable codes and project specification. It typically covers:
- Ignition and flame monitoring systems
- Instrumentation and electrical equipment suitable for hazardous areas (ATEX/DSEAR as applicable)
- Design aligned with relevant EN / ASME requirements (and other codes where specified)
- A complete technical dossier prepared for HAZOP, integrity reviews and safety audits
Why choose AITESA for industrial flares?
In refining, chemicals or hydrogen, flares are not selected from a catalogue. They are validated by engineering, process safety and compliance. That is why we start early with clear design criteria, integration requirements and documentation ready for internal reviews (including HAZOP).
What we bring:
- Single-scope engineering and supply: flare system design, selection of arrangement (elevated or enclosed) and integration with the relief header and utilities.
- Designed for real operating conditions: stable combustion across variable flows/compositions, solutions for low-calorific-value gases and hydrogen services.
- Process safety and compliance: hazardous-area considerations, safety barriers, ignition/detection logic, and thermal radiation/noise assessment per site constraints.
- A technical package for engineering and procurement: design basis, calculations, drawings and documentation to speed up internal approvals, audits and bid cycles.
- Industrial and international experience: projects in sectors with demanding availability, safety and emissions expectations.
Combustion fundamentals and emissions performance
Flare performance depends on gas–air mixing quality, flame stability and operating conditions. Design targets the most complete combustion achievable, considering gas composition, flow variability and environmental requirements.
Operational factors that influence design include:
- CO: typically linked to insufficient mixing or uneven air distribution
- NOₓ: depends on flame temperature, composition and operation; addressed in the design where requirements apply
For elevated flares, the flare tip and configuration (single/multi-tip, assisted operation where required) are critical to stability and combustion quality.
Handling low-calorific-value gases
When the gas has a low heating value, flame stability can be compromised. In these cases, the flare can be designed to operate with support gas to ensure reliable ignition and sustained combustion.
This enables safe, controlled handling of low-calorific-value streams, defining from the outset the stabilisation strategy and operational requirements.
Engineering-led supply, not a standalone item
A flare should not be treated as an isolated piece of equipment, but as a plant system governed by real operating conditions. From early phases we incorporate process, safety and site constraints to deliver a solution that is installable, operable and maintainable.
Depending on project needs, this approach can include coordination of structures and associated pipework to ensure mechanical integrity and compatibility with the existing installation.
Typical scope and deliverables
Scope is project-specific, but to accelerate technical definition and reduce iterations we work with a deliverables set focused on engineering and safety validation:
- Design basis and scenario definition (normal, minimum, maximum and relief cases)
- Selection of flare type and siting criteria (radiation, noise, visual impact)
- Sizing and combustion criteria (flame stability, gas–air mixing, assisted operation where applicable)
- Plant integration and relief header interfaces: key tie-ins, layout/space envelope and integration constraints aligned with plant philosophy
- Documentation for internal review: design basis, main criteria, agreed drawings and a technical data list/specification sheets (including HAZOP support where applicable)
Need to define scope before requesting quotations?
Describe your situation and your concerns. We will get back to you within 48 hours to align on a flare solution that fits your operation and site requirements.
Operational and maintenance benefits
An engineering-led approach translates into reliable, safe operation across the flare system’s service life.
Key plant benefits:
- Stable combustion even with variable flows and composition
- Optimised gas–air mixing to reduce CO formation and maintain appropriate NOₓ control
- Design suitable for high-reactivity gases, including hydrogen
- Robust construction and material selection to reduce maintenance effort and improve availability
Industrial applications
We design flare systems for integration across a wide range of industrial sites, particularly where process safety and emissions control are critical:
- Green hydrogen production facilities
- Refineries and petrochemical plants
- Industrial sites with flare/relief systems
- Steelmaking and coke oven gas services
- Gas treatment and recovery/valorisation facilities
At AITESA we are experts in the design of heat recovery boilers type HRSG and WHRB.
Frequently Asked Questions
What information do you need to size the system and prepare a quotation?
To confirm feasibility and size a flare system properly, we typically need at least:
- Gas composition and variability
- Flow ranges (minimum, normal, maximum) plus relief/vent scenarios
- Heating value and whether the stream is low-calorific
- Site constraints (visual impact, thermal radiation and noise limits)
- Hazardous-area classification and requirements (ATEX/DSEAR as applicable)
- For hydrogen services: O₂ presence/range and associated operating conditions
Which flare is better: elevated (visible flame) or enclosed ground flare?
It depends on site constraints and environmental requirements:
- Elevated flares are common in refineries and industrial plants; combustion occurs at the tip in open air and gases are discharged at elevation.
- Enclosed (ground) flares are selected where visual impact, radiation or noise must be limited; combustion takes place within an enclosure with controlled air admission, typically via natural draught.
What if the gas has a low heating value?
With low-calorific streams, flame stability can be affected. The system can be designed with support gas to ensure ignition and sustained combustion while keeping operation safe and controlled.
What is different about a flare for hydrogen service?
Hydrogen service needs a specific approach due to high reactivity, low ignition energy and the potential presence of oxygen (for example, from electrolysis). Upstream, the system can include flow/composition measurement. Where there is excess O₂, controlled methane injection can be incorporated to balance the mixture and maintain stable, safe combustion.
What does “process safety and compliance” include in a flare system?
Process safety is central to the design. The package typically includes:
- Ignition and flame detection systems
- Instrumentation and electrical equipment suitable for hazardous areas (ATEX/DSEAR as applicable)
- Design aligned with applicable EN / ASME requirements (and other codes where specified)
- Documentation ready for engineering reviews and HAZOP, plus safety audits
What is included in AITESA’s scope for a flare system?
Scope is defined project by project to match your plant philosophy and delivery model (end user or EPC). Typically we cover design and supply of the flare system and its engineering-level integration (design criteria, key interfaces and documentation for review).
During the bid phase we clearly delimit what equipment, instrumentation and associated works are included and what remains within plant/EPC scope.
Talk to an expert