How to specify a shell and tube heat exchanger: TEMA classes, flow configuration and design criteria
By AITESA
Introduction
A technical guide to defining the service, selecting the appropriate TEMA class and configuration, and balancing heat transfer, pressure drop, fouling, materials and maintenance.
Specifying a shell and tube heat exchanger is not simply a matter of defining the required heat duty and selecting a heat transfer area.
Two units may appear to meet the same heat duty and yet behave very differently once available pressure drop, fouling, corrosion, thermal expansion, ease of cleaning and actual operating conditions are taken into account.
For this reason, specification should start with the process and end with a mechanical configuration that is consistent with it. The TEMA class, fluid arrangement, number of passes, tube bundle configuration, materials and maintenance criteria all form part of the same design decision.
In a well-defined RFQ, the better these conditions are specified, the lower the uncertainty during sizing and the easier it becomes to compare technically equivalent solutions.
Specification starts with the process conditions
Before selecting a TEMA class or configuration, it is necessary to define what the heat exchanger actually needs to do.
The heat duty determines how much heat must be transferred, but it does not define the equipment on its own. Flow rates, inlet and outlet temperatures, operating and design pressures, fluid properties, any phase changes and the available pressure drop must also be known.
Other parameters also have a direct influence on the design: fouling tendency, corrosiveness, the presence of solids, cleaning requirements, start-up and shutdown conditions, possible upset scenarios, and space or integration constraints.
Mechanical selection should take place once the conditions the equipment must withstand have been defined. This becomes even more important in replacement or revamp projects: the new exchanger must not only achieve the required heat duty, but do so within the connections, space, pressure-drop limits and operating conditions imposed by the existing installation.
TEMA R, B or C: the class must match the service
TEMA standards define three main classes for shell and tube heat exchangers: R, B and C. Class R is intended for severe petroleum and related processing applications; Class B for chemical process service; and Class C for commercial and general process applications.
These classes should therefore not be interpreted simply as a scale on which R is a ‘better’ exchanger than B or C. The relevant question is which class is appropriate for the service, design conditions and client specification.
In refining and certain petrochemical applications, for example, there may be additional project requirements associated with API 660, TEMA, pressure-vessel codes and end-user specifications. TEMA and the mechanical design code do not perform exactly the same function either: the exchanger class and the applicable design code are related, but distinct, decisions.
Selecting the class before fully understanding the service can result either in insufficient requirements or in specifications that add unnecessary complexity and cost to the equipment.
TEMA class and TEMA configuration are not the same decision
Another common source of confusion is using ‘TEMA’ as though it described a single characteristic of the exchanger.
In addition to Classes R, B and C, TEMA uses a three-letter designation to identify the equipment configuration: the type of front-end head, shell configuration and rear-end head.
This choice has significant implications for operation and maintenance. A fixed-tubesheet design, a U-tube bundle or a floating-head configuration may all achieve the same thermal objective, but they respond differently to differential thermal expansion, inspection access, tube-bundle removal and mechanical cleaning.
Defining ‘TEMA R’ or ‘TEMA B’ therefore does not complete the specification. The mechanical configuration that can meet the thermal, hydraulic and maintenance requirements of the service must still be determined.
Flow configuration affects the required heat transfer area
The relative direction of the two fluids directly affects the driving force for heat transfer.
In an ideal counterflow arrangement, the two fluids travel in opposite directions, maintaining a more favourable temperature difference along the exchanger. Compared with a purely parallel-flow arrangement, this generally provides a higher logarithmic mean temperature difference (LMTD) for the same terminal temperatures.
Q = U · A · ΔTlm · F
Q: heat duty · U: overall heat transfer coefficient · A: heat transfer area · ΔTlm: logarithmic mean temperature difference · F: correction factor for the actual configuration
The correction factor is important because an industrial shell and tube heat exchanger rarely behaves as an ideal counterflow exchanger. The number of tube passes, shell passes and the geometry itself alter the temperature profile, so the LMTD must be evaluated for the final arrangement selected.
‘Designing for counterflow’ should therefore not become an isolated rule. The thermal configuration must be assessed together with the geometry, pressure drop and mechanical constraints of the equipment.
More passes can improve one variable while penalising another
Increasing the number of passes can raise fluid velocity and improve the heat transfer coefficient. However, it also generally increases pressure drop.
This trade-off is one of the reasons why heat exchanger sizing cannot be optimised by considering heat transfer area alone.
Insufficient velocity can encourage deposits or reduce the heat transfer coefficient. Excessive velocity can increase pressure drop and, depending on the fluid and materials, introduce additional erosion or vibration concerns.
The same applies on the shell side. Baffle configuration and spacing affect the fluid path, cross-flow velocity over the tube bundle, heat transfer and pressure drop. The final design must satisfy both the required heat duty and the hydraulic constraints of the process.
Fouling must be considered from the start of the design
The exchanger is sized to operate throughout its service life, not simply to perform well when it is clean.
The nature of both fluids, their tendency to form deposits or scale, and the intended cleaning method affect both the required surface area and the mechanical configuration.
The fouling factor should therefore not be treated simply as a margin added at the end of the calculation. It has implications for the overall heat transfer coefficient, velocities, tube pitch, accessibility of the bundle and the maintenance strategy.
In some applications, accepting a mechanically more complex solution may be preferable if it facilitates inspection and cleaning over the life of the equipment. In others, with clean fluids and stable conditions, a simpler construction may be sufficient.
The objective is not to maximise any one characteristic in isolation, but to identify a solution that is compatible with the expected behaviour of the service.
Deciding which fluid goes on the tube side and which on the shell side is also part of the specification
The allocation of fluids to the tube side or shell side should not be automatic either.
Pressure, corrosiveness, fouling, viscosity, flow rate, phase change, allowable pressure drop, material cost and cleaning requirements can all influence the decision.
In some cases, it may be advantageous to contain a high-pressure fluid within the tubes. In others, ease of cleaning, thermal behaviour or the required geometry may favour a different arrangement.
The decision must be assessed together with the rest of the design because it affects velocities, heat transfer coefficients, pressure drop, materials and mechanical configuration.
Materials, thermal expansion and maintenance complete the specification
A correct thermal specification can still result in unsuitable equipment if the actual mechanical conditions are not considered.
Material selection depends on chemical compatibility, temperatures, expected corrosion and the requirements of the applicable code. At the same time, temperature differences between the shell and tubes can generate differential thermal expansion and influence the tube bundle configuration.
It is also necessary to anticipate how the equipment will be inspected and maintained. The space available for tube-bundle removal, access to the tube sheets, the cleaning method and maintenance shutdown windows can all change the optimum solution before the exchanger is even manufactured.
In brownfield projects, these constraints carry even greater weight because the equipment must be integrated into an installation whose geometry, pipework and maintenance procedures already exist.
What information should be included in an RFQ?
To begin the design on a sufficiently robust technical basis, the specification should include at least:
- Service and required heat duty.
- Flow rates and properties of both fluids.
- Inlet and outlet temperatures.
- Operating and design pressures.
- Fluid phases and any possible phase changes.
- Maximum allowable pressure drop in each circuit.
- Fouling tendency and cleaning criteria.
- Corrosiveness and material restrictions.
- Design, operating, start-up, shutdown and relevant upset conditions.
- Mechanical design code, TEMA class and client specifications, where already defined.
- Dimensional constraints, existing connections and maintenance or tube-bundle removal requirements.
Not all of these parameters need to be fully defined at the first enquiry. However, identifying the information that is still missing helps prevent the preliminary sizing from relying on assumptions that later affect the equipment size, cost or even its configuration.
A good specification avoids optimising the wrong exchanger
The aim when specifying a shell and tube heat exchanger is not to achieve the highest LMTD, the smallest surface area or the most demanding TEMA class independently.
The design must balance heat transfer, pressure drop, fouling behaviour, materials, mechanical integrity, maintainability, available space and life-cycle cost.
The TEMA class defines part of the mechanical requirements. The configuration determines how the equipment is constructed and maintained. The flow arrangement affects how effectively the temperature difference is used. The number of passes changes heat transfer and pressure drop. And the actual process conditions determine whether all these decisions work together.
This is the difference between selecting an exchanger from a catalogue and specifying equipment for a specific industrial installation.
Talk to an expert
If a new shell and tube heat exchanger is being specified, or the replacement of an existing unit is being assessed, the available process conditions, operating constraints and integration requirements can be shared with AITESA. The technical team will review the initial information to understand the project requirements and propose the most appropriate configuration.